Autel Ecomatic S Manual: Your Complete Guide & Troubleshooting

Are you seeking comprehensive information about the Autel Ecomatic S Manual? CARDIAGTECH.NET offers expert insights and practical advice for optimizing your dust collector system. We provide solutions that save you time and money. Enhance your system now by understanding essential maintenance and operational procedures, including pressure adjustments and timer settings for dust collector system efficiency.

1. Introduction to the Autel Ecomatic S

The Autel Ecomatic S series comprises digital sequential timers equipped with integrated differential pressure switches. These economizers are designed to efficiently control solenoid valves in dust collection systems. The series includes models such as ECOMATIC-S4, ECOMATIC-S6, ECOMATIC-S12, ECOMATIC-S20, and ECOMATIC-S32, which can manage up to 4, 6, 12, 20, and 32 solenoid valves, respectively.

For larger systems, the ECOMATIC-S64 features an expansion card, extending control to 64 solenoid valves. The ECOMATIC-S96 further expands this capacity with two expansion cards, supporting up to 96 solenoid valves. All models include a 3-digit display that shows differential pressure in various units (tens Pa, mmH2O, mbar, kPa, and mmHg) or indicates the cleaning valve number.

The controllers also feature LEDs that indicate output activation, pause phases, power status, and post-cleaning status. Models with AC power supply support both AC and 24VDC electronic valves. The output stage uses zero-crossing triacs to minimize noise. Each unit is housed in a polycarbonate enclosure with a transparent lid and an IP56 protection rating. Optionally, ECOMATIC-S devices can include an active analog output proportional to the sensor-read pressure.

2. General Technical Features

Understanding the general technical features of the Autel Ecomatic S is crucial for optimal performance and maintenance. These features ensure the system operates efficiently and reliably within specified parameters.

2.1. Voltage and Power Supply

The Autel Ecomatic S supports multiple voltage options to suit different power supply standards.

Voltage Options Specification
Supported Voltages 24 Vac, 115 Vac, 230 Vac +/- 15%, 50-60Hz

2.2. Fuses

The Ecomatic S series uses specific fuses to protect against electrical overloads, ensuring the safety and longevity of the device.

Model General Fuse Electrovalves Fuse
ECO-S 4/6, 12 F2: 2A 5×20 rapid F4: 1.6A 5×20 delayed
ECO-S 20/32/64/96 F1: 2A 5×20 rapid F2: 1.6A 5×20 delayed

2.3. Environmental Conditions

The device is designed to operate within a specific temperature range to maintain performance and prevent damage.

Environmental Condition Specification
Working Temperature -10 / +50 °C

2.4. Connectivity

Connectivity options include screw terminal boards for easy and secure connections.

Connectivity Type Description
Connection Method Through screw terminals boards

2.5. Power Consumption

Maximum power consumption ensures that the device operates within acceptable energy usage limits.

Power Metric Specification
Max Adsorbe Power 50VA

2.6. Inputs and Outputs

The Autel Ecomatic S includes several inputs and outputs to integrate with other systems and components.

Input/Output Type Ecomatic-S 4/6/12/20/32/64/96 Ecomatic-S 20/32/64/96
Opto-isolated Inputs 1 1
Relay Outputs 1 (2A resistant load 115Vac) 4 (2A resistant load 115Vac)
Electrovalves Output Triac, zero-crossing activation/deactivation, 24, 115, 230 Vac, 24Vdc, max. 2A Triac, zero-crossing activation/deactivation, 24, 115, 230 Vac, 24Vdc, max. 2A

3. Technical Features of the Timer

The timer features of the Autel Ecomatic S are critical for controlling the cleaning cycles efficiently. These settings allow for precise adjustments of pause, work, and post-cleaning times, optimizing the performance of the dust collection system.

3.1. Pause Times

Pause times determine the interval between the activation of solenoid valves, allowing the system to stabilize.

Feature Specification
Duration 1- 999 sec
Precision 0,1 sec

3.2. Working Times

Working times define how long each solenoid valve is activated during the cleaning cycle.

Feature Specification
Duration 0.03 – 9.99 sec
Precision 0,01 sec

3.3. Post Cleaning Times

Post-cleaning times set the duration for additional cleaning after the primary cycle, ensuring thorough dust removal.

Feature Specification
Duration 1 – 999 sec
Precision 0,1 sec

4. Active Analog Output (Optional)

The optional active analog output feature allows for real-time monitoring and control of pressure via analog signals. This can be particularly useful for integrating the Ecomatic S with other control systems.

4.1. Current Output

The current output provides a signal proportional to the measured pressure, typically ranging from 4.0 to +20.0 mA.

Feature Specification
Visualization Range From 4.0 to +20.0 mA (standard) / From 0.0 to +20.0 mA (optional)
Precision +/- 0.1 mA, +/- 1 digit
Maximum Load 500 Ohm

4.2. Voltage Output

Alternatively, a voltage output can be used, typically ranging from 0.0 to +5.0 V or 0.0 to +10.0 V.

Feature Specification
Visualization Range From 0.0 to +5.0 V (optional) / From 0.0 to +10.0 V (optional)
Precision +/- 0.1 V, +/- 1 digit
Minimum Load 1K Ohm

5. Dimensions and Features of the Ecomatic S Box

The physical dimensions and features of the Ecomatic S box are important for installation and ensuring environmental protection.

5.1. Box Dimensions

The Ecomatic S comes in various box sizes depending on the model, each designed to offer adequate protection and space for internal components.

Model Internal Dimensions (BxHxP) (mm) Max Allowed Holes (Ø) Top Screws (n. and type)
ECOMATIC-S 4/6 190 x 140 x 70 37 mm 4 isol. Zipper pouncable
ECOMATIC12-S 240 x 190 x 90 37 mm 4 isol. Zipper pouncable
ECOMATIC-S 20/32/64/96 380 x 300 x 120 48 mm 4 isol. Zipper pouncable

5.2. Box Material and Protection

The boxes are typically made from polycarbonate with a transparent lid, offering an IP56 protection rating.

Feature Description
Material Polycarbonate
Lid Transparent
Protection Rating IP56 (Dust-tight and protected against strong water jets)

6. Layout and Legend of the Ecomatic S Board

Understanding the layout and legend of the Ecomatic S board is essential for proper installation, maintenance, and troubleshooting.

6.1. Ecomatic S 4/6 Layout

Component Description
F2 Power supply protection fuse
F4 Electrovalves protection fuse
Power Supply Terminals Terminals for connecting the power supply
Input Contacts Terminals Terminals for post-cleaning input
Relay Output Terminals Terminals for relay contact 1 (K1)
Auxiliary Outputs Terminals Optional terminals for expansion board 4-20mA
Display 7 Segments 3 DIGIT Display for showing pressure, output number, etc.
Enter Key (E) Key to enter programming menu and confirm settings
Decrease Key (↓) Key to decrease values in the programming menu
Increase Key (↑) Key to increase values in the programming menu
Common Terminal Common terminal for electronic valves
Common Terminal + 24Vdc Common terminal with +24Vdc for 24Vdc electronic valves

6.2. Ecomatic 12-S Layout

Component Description
F2 Power supply protection fuse
F4 Electrovalves protection fuse
Power Supply Terminals Terminals for connecting the power supply
Input Contacts Terminals Terminals for post-cleaning input
Relay Output Terminals Terminals for relay contact 1
Auxiliary Outputs Terminals Optional terminals for expansion board analogical output
Display 7 Segments 3 DIGIT Display for showing pressure, output number, etc.
Enter Key (E) Key to enter programming menu and confirm settings
Decrease Key (↓) Key to decrease values in the programming menu
Increase Key (↑) Key to increase values in the programming menu
Common Terminal Common terminal for electronic valves
Common Terminal + 24Vdc Common terminal with +24Vdc for 24Vdc electronic valves

6.3. Ecomatic S 20/32/64/96 Layout

Component Description
F1 Power supply protection fuse
F2 Electrovalves protection fuse
Power Supply Terminals Terminals for connecting the power supply
Input Contacts Terminals Terminals for post-cleaning input
Relay Output Terminals Terminals for relay contact 1 (K1)
Auxiliary Outputs Terminals Optional terminals for expansion board analogical output
Display 7 Segments 3 DIGIT Display for showing pressure, output number, etc.
Enter Key (E) Key to enter programming menu and confirm settings
Decrease Key (↓) Key to decrease values in the programming menu
Increase Key (↑) Key to increase values in the programming menu
Common Terminal Common terminal for electronic valves
Common Terminal + 24Vdc Common terminal with +24Vdc for 24Vdc electronic valves
On/Off Power Switch Switch to turn the device on or off

7. Technical Features of the Differential Gauge

The differential gauge in the Autel Ecomatic S is crucial for measuring pressure differences, which are used to trigger cleaning cycles.

7.1. Measurement Units and Ranges

The Ecomatic S supports multiple measurement units for pressure, allowing users to select the most convenient unit for their application.

Measurement Unit Measurement Range
dPa -99 to +999
mmH2O -99 to +999
mbar -9.9 to +99.9
KPa -0.99 to +9.99
mmHg -7.5 to +75.0

7.2. Precision and Broken Pressure

The gauge offers high precision and is designed to withstand high pressures without damage.

Feature Specification
Precision +/- 1% F.S., +/- 1 digit
Broken Pressure 0.5 bar (5000 mmH2O)

7.3. Conversion Chart

A conversion chart is essential for translating between different units of pressure.

Unit mmH2O pascal mbar kpascal mmHg
mmH2O 1 0.101974 10.1974 101.974 13.5951
pascal 9.8064 1 100 1000 133.3224
mbar 0.098064 0.01 1 10 1.333224
kpascal 0.0098064 0.001 0.1 1 0.1333224
mmHg 0.07355592 0.007500617 0.7500617 7.500617 1

7.4. Temperature Range

The inlet gas temperature range is crucial for maintaining the accuracy and reliability of the pressure sensor.

Feature Specification
Temperature Range -40 °C to +125 °C

8. Ecomatic S Power Supply

Proper power supply is crucial for the reliable operation of the Autel Ecomatic S.

8.1. Voltage Options

The Ecomatic S models support various voltage options, ensuring compatibility with different power systems.

Voltage Option
24 Vac
115 Vac
230 Vac

8.2. Power Supply Connection

Connecting the power supply correctly is vital to avoid damage and ensure proper operation. Always disconnect the power supply before making or modifying cable connections.

Voltage Terminal
24Vac 0
115Vac 0
230Vac 0

8.3. Important Notes

  • Ensure the power supply is disconnected upstream of the equipment.
  • Always ground both the economizers and electrovalves.
  • Use shielded cables, kept away from noise sources such as inverter power cables and engines.

9. Electrovalves Connection Scheme

Properly connecting the electrovalves is essential for the Ecomatic S to control the dust collection system effectively.

9.1. Connection Method

The solenoid valves are connected between the output terminals 1-2 … – N and terminal C (common), which is connected to a suitable power supply via an external connection.

9.2. Voltage Compatibility

The type of electrovalves that can be used depends on the power supply voltage given to the unit.

Power Supply Compatible Electrovalves
24 Vac 24 Vac or 24 Vdc
115 Vac 24 Vac, 115 Vac, or 24Vdc
230 Vac 24 Vac, 115 Vac, 230 Vac, or 24 Vdc

9.3. Load Connection

An external bridge connected according to the voltage of the used electronic valves must be made for the load’s connection. This connection is made between the terminal C (common) and the power supply terminal, corresponding to the operating power of the electro valves.

9.4. Control of Electrovalves in Parallel

ECOMATIC-S cards can control up to 2 Electrovalves for a single output, or activate up to 4 outputs simultaneously for 110V/220V power supply and 2 outputs at the same time for 24VAC/DC power supply.

9.5. Important Cautions

  • To activate more than one electrovalve in parallel or on various outputs, ensure that the valves and instrument power supply have the same voltage.
  • In all ECOMATIC-S models, driving two electrovalves at the same time requires changing the fuse values on the board:
    • The general protection fuse of 2A quick must be changed to 4A quick.
    • The load protection fuse of 1.6A delayed must be changed to 3.15A delayed.
  • For ECOMATIC-S 64/96 versions, the connection of double electrovalves to the outputs on the expansions must follow the specified scheme.
  • Ensure the cables of electrovalves are kept away from noise sources, such as inverter power cables and engines.

10. Display Visualization

The display of the Autel Ecomatic S provides essential information about the system’s status and performance.

10.1. Menu Structure

The display visualization is divided into multiple menus, each providing different types of information.

Menu Description
1st Menu Pressure value read by the instrument
2nd Menu System status, output number, or cleaning command
3rd Menu Value of the analogical output (if enabled)

10.2. Pressure Value (1st Menu)

The first menu displays the pressure value along with a unit identifier.

Identifier Unit
0 tens Pascal
1 mmH2O
2 mbar
3 KPa
4 mmHg

10.3. System Status (2nd Menu)

The second menu indicates the system’s current status.

Status Indication
STOP or almost in stop S.xx
CLEANING U.xx
POSTCLEANING P.xx

10.4. Analogical Output (3rd Menu)

If the analogical output is enabled, the third menu displays its value.

Output Type Visualization
Current Cor.
Tension Vol.

11. Errors Visualization

The Autel Ecomatic S provides error codes on the display to help diagnose and troubleshoot issues.

11.1. Pressure Error

Pressure errors indicate that the input differential pressure is outside the set range.

Error Code Description
EEE Input differential pressure is higher than the positive full scale set
-EE Pressure is lower than the negative full scale set

11.2. E2PROM Error

An E2PROM error indicates problems with the configuration memory.

Error Code Description
Loss of programming and setting data in the E2PROM

To resolve an E2PROM error, press the Dec (↓) key to reload the default data. You will then need to reset and reprogram the instrument.

12. Preliminary Procedures

Before operating the Autel Ecomatic S, certain preliminary procedures must be followed to ensure proper functionality.

12.1. Initial Setup

Upon powering up the unit, it will display the differential pressure value read by the internal sensor.

12.2. Navigation

Use the Inc (↑) or Dec (↓) buttons to view the pressure, the number of the valve in cleaning, and the value of the analogical output (if enabled).

12.3. Accessing the Programming Menu

To enter the programming menu, press the E key. The first parameter, L1, will appear.

12.4. Parameter Scrolling

Press the Inc or Dec keys to scroll through the parameters one by one.

12.5. Exiting the Programming Menu

The system will automatically exit the programming menu if no key is pressed for 10 seconds.

13. Programmation Parameters

The programmation parameters of the Autel Ecomatic S allow you to customize the system’s operation to meet specific requirements.

Parameter Function Possible Values Further Information
L1 Hour counter 0 – 65534 hours Hour counter functioning
L2 Cycle counter 0 – 65534 cycles Cycle counter functioning
P1 Pause time 1 – 999 seconds
P2 Working time 0.03 – 9.99 seconds
P3 Value of time or cycles for post-cleaning 1 – 999 seconds / 1 – 999 cycles
P4 Post-cleaning function 0=Disabled / 1=Internal / 2=External Post-cleaning functioning
P5 Unit pressure measure 0 = tens Pa / 1 = mmH2O / 2 = mbar / 3 =Kpa / 4 = mmHg Unit pressure measure
P6 Post-cleaning time or cycles selection 0= Time / 1= Cycles Post-cleaning functioning
P7 Manual/Auto 0=Manual / 1=Automatic Automatic and Manual functioning
P8 Start cleaning pressure From 0 to F.S. positive Automatic functioning
P9 End cleaning pressure From 0 to F.S. positive Automatic functioning
P10 Internal post-cleaning pressure threshold From 0 to F.S. positive Post-cleaning functioning
P11 Relay 1 pressure threshold From 0 to F.S. positive Relay Output functioning
P12 Enable precoating 0=Disabled / 1=Enabled Precoating Functioning
P13 Precoating threshold From 0 to F.S. positive Precoating Functioning
P14 Pressure value for minimum analog output From 0 to F.S. positive Analog output functioning
P15 Pressure value for maximum analog output From 0 to F.S. positive Analog output functioning
P16 Relay 1 functioning selection 0–1 Relay Output functioning
P17 Function of relay 1 0=Normal / 1=Temporized / 2=Hysteresis pressure Relay Output functioning
P18 Value of relay 1 function From 1 to F.S. positive or 1 – 999 seconds Relay Output functioning
P19 Pause time in post-cleaning mode 1 – 999 seconds Post-cleaning functioning
H0 Pressure zero To be done by specialized staff only

14. Ecomatic S Function

The Autel Ecomatic S offers both manual and automatic modes for cleaning filters, each with its advantages.

14.1. Manual Mode

In manual mode, the Ecomatic S drives the outputs corresponding to the connected valves one by one, regardless of any programming.

  • Outputs are driven sequentially, starting from the first electrovalve.
  • Working time and pause time alternate between the activation of outputs.

14.2. Automatic Mode

In automatic mode, the electrovalves are activated based on the visualized pressure compared to the set parameters.

  • Electrovalves activate if the visualized pressure exceeds the starting cleaning pressure (P8).
  • Activation stops when the pressure drops below the end cleaning pressure (P9).
  • The cycle stops only if the Ecomatic S is in the pause phase and after the last valve of the cycle.

15. Pressure Tubes Connection Scheme

Proper connection of pressure tubes is essential for accurate pressure measurement and reliable operation of the Autel Ecomatic S.

15.1. Connection Layout

The pressure tubes should be connected as follows:

  • ECOMATIC-S 4/6/12: Follow the specific layout for these models to ensure correct pressure readings.
  • ECOMATIC-S 20/32/64/96: Use the designated connection points for these models.

15.2. Filtered Outlets

Installing filtered outlets is recommended to limit potential failures of the internal pressure sensor.

  • These filters prevent dust and other substances from reaching the pressure sensor.
  • Mount the filters directly on the filter where they are usually positioned in the outlet pipes.
  • It is recommended to install a filtered outlet for each pressure tube applied.

15.3. Pressure Hose

Use Rilsan type 6×4 pressure hose for optimal performance.

  • Connect the positive nozzle of the instrument to the dirty room.
  • Connect the negative nozzle to the clean room of the filter.

15.4. High-Temperature Considerations

For temperatures above 125 °C, reduce the level of inlet sensor temperature to fall within the permissible range (-40 °C / 125 °C). Use a length of copper tubing to dissipate excess heat.

16. Pressure Zero Setting

During operation, the pressure displayed may slightly differ from the actual pressure due to changing conditions. To restore correct pressure readings, you must perform a pressure zero setting.

16.1. Procedure

  1. Enter the programming menu using the E key.

  2. Ensure the jets of grafting of the tubes are free, i.e., not connected to the pipes from the air filter.

  3. Press Inc to select parameter H 0.

  4. Follow these steps:

    • Press E (the message 0 flashes).
    • Wait 4 or 5 seconds.
    • Confirm the reset by pressing the E key again (the display shows H 0 again).
    • Wait 10 seconds for the display to return to the pressure value and verify that the reading is 0.

16.2. Important Cautions

  • Reset pressure (parameter H 0) only if the pressure reading on the display with outlets open is notably different from zero.
  • This operation must be carried out exclusively by skilled personnel and only after the instrument has been switched on for at least 15 minutes.

17. Outputs Test Activation Function

The output test activation function is used to test each output during testing, maintenance, or troubleshooting.

17.1. Procedure

  1. Use the Dec (↓) key to navigate to the number visualization of the active output.
  2. Simultaneously press the Inc (↑) and Dec (↓) keys to enter the test outputs menu.
  3. The number of outputs by activating will flash.
  4. To activate the visualized output, press the E key.
  5. To change the number of the output, use the Inc (↑) and Dec (↓) keys.
  6. The minimum time that must pass for a shot through the following key E is 1 second.

17.2. Returning to Normal Cycle

To return to the normal cycle of operation, simultaneously press all three keys.

18. Active Analogical Output Functioning (Optional)

The Autel Ecomatic S can provide a current or tension output that changes linearly with pressure.

18.1. Current Output

  • It is possible to generate a current that changes linearly between 4-20mA or between 0-20mA through the programming of P 14 and P 15 parameters.
  • P 14 corresponds to the pressure required to obtain a current output of 4mA or 0mA.
  • P 15 corresponds to the pressure required to obtain a current output of 20mA.
  • Maximum applicable load: 500ohm.

18.2. Tension Output

  • It is possible to generate a tension that changes linearly between 0-10V or 0-5V through the programming of P 14 and P 15 parameters.
  • P 14 corresponds to the pressure required to obtain a current equal to 0V.
  • P 15 corresponds to the pressure required to obtain a current equal to 5V or 10V.
  • Minimum applicable load: 1Kohm.

18.3. Analogical Output Connection

The connection between the ECOMATIC-S and the expansion card 4-20 mA and a potential external must be performed using the following terminals based on the instrument model:

  • For ECOMATIC-S 4/6, terminals n°5 (+), n°6 (-) and n°7 (earth).
  • For ECOMATIC-S 12/20/32/64/96, terminals +, – and earth as indicated in the printed circuit board.

19. Hours Counter Function

The hours counter tracks the operational hours of the system.

19.1. Visualization

The value of the hours counter can be viewed in parameter L 1 from the programming menu.

19.2. Operation

The hours counter starts counting when the pressure visualized on the display is higher or equal to the pressure set in parameter P 10 (post-cleaning pressure).

19.3. Maximum Value

The maximum value that can be set for the number of hours is “65534”, after which the counter resets automatically.

19.4. Displaying Large Numbers

Although the instrument has a 3-digit display, numbers up to 5 digits can be displayed using a flashing indicator.

  • If the left number flashes, there are remaining numbers to the left.
  • If the right number flashes, there are remaining numbers to the right.
  • If both numbers flash, there are remaining numbers to both the left and right.

20. Cycles Counter Function

The cycles counter tracks the number of operation cycles performed during output scanning.

20.1. Access and Display

Parameter L2 enables access and display of the counter monitoring operation cycles performed during output scanning.

20.2. Counting

Counting is done every time one complete cycle of activation of outputs, even if these are not connected.

20.3. Maximum Cycles

The total number of possible cycles is “65534”, after which all stored values in the counter memory are reset.

20.4. Display Method

The method to display the number of cycles is the same as described above for the hour counter.

21. Relay Outputs Functioning

The relays on the ECOMATIC-S have various functioning modes, selectable in the programming menu.

21.1. Functioning Modes

Each relay is independent, with its own parameters, and can be activated differently. The possible functioning modes are:

  1. = 0 as minimum relay:
    • Standard
    • Temporized
    • Hysteresis pressure
  2. = 1 as maximum relay:
    • Standard
    • Temporized
    • Hysteresis pressure

21.2. Standard Minimum and Maximum Relay

  • Minimum Standard Relay: Set the value 0 in parameter P 16 and P 17, and set the pressure value of relay work in P 11. The relay will be activated when the pressure is equal to or less than the pressure in P 11.
  • Maximum Standard Relay: Set the value 1 in parameter P 16 and value 0 in parameter P 17, and set the pressure value of relay work in P 11. The relay will be activated when the pressure is greater than the pressure in P 11.

21.3. Temporized Output

The temporized output allows the relay to be activated with a settable pressure gap.

  • Minimum Temporized Relay: Set the value 0 in P 16, the pressure value for the relay in P 11, the value 1 in P 17, and the time value in P 18. The relay will be activated after the set time when the pressure is equal to or less than the pressure